The Sysmex XN-1000 is a compact, benchtop hematology analyzer that uses advanced fluorescence flow cytometry to provide comprehensive Complete Blood Counts (CBC) (CBC) and differentials, including immature granulocytes (IG), and specialized body fluid analysis with high throughput (up to 100 samples/hr) and automated rerun/reflex testing, reducing manual work and improving efficiency in clinical labs. It offers reliable, accurate results with advanced flagging for potential disorders like iron deficiency or hemoglobin defects, making it a valuable tool for modern diagnostics.

Measurement principles
WBC DIFF/RET/PLT-F/WPC: Fluorescence Flow Cytometry
RBC/PLT: Hydrodynamically focussed impedance
HGB: Cyanide-free SLS haemoglobin

Aspiration volume
88 ยตL in whole blood (WB) mode and body fluid (BF) mode

Throughput
up to 100 samples/h

Quality control material
XN Check (three levels) and XN Check BF (two levels)

Parameters
XN-CBC (always with NRBC) & XN-DIFF (always with IG)

Whole Blood
WBC, NRBC%, NRBC #, RBC, HGB, HCT, MCV, MCH, MCHC, PLT, RDW-SD, RDW-CV, MicroR%, MacroR%, PDW, MPV, P-LCR, PCT, NEUT%, NEUT #, LYMPH%, LYMPH #, MONO%, MONO #, EO%, EO #, BASO%, BASO #, IG%, IG #

With RET (optional)
RET%, RET #, IRF, LFR, MFR, HFR, RET-He, RBC-He, Delta-He, HYPO-He%, HYPER-He%, PLT-O

With PLT-F (optional)
PLT-F, IPF, IPF #

With WPC (optional)
Extended Inflammation Parameters licence: NEUT-GI, NEUT-RI, RE-LYMP%, RE-LYMP #, AS-LYMP%, AS-LYMP #

XN Stem Cells licence
HPC%, HPC #

Body Fluids with XN-BF
WBC-BF, RBC-BF, MN%, MN #, PMN%, PMN #, TC-BF #
(optional)

Model: XN-1000
Brand: Sysmex
Origin: Japan
Distributor: BioTech Services

05/12/2025

V8 NEXUS
Automated Clinical Capillary Electrophoresis
Capillary Electrophoresis is the best for Hb variant separation!

Eight capillaries, six buffers and ten reagents on-board for multi-assay use.

Proteins - 88 Tests/hr
Hemoglobins - 16 Test/hr
Immunodisplacement - 14 Test/hr

Up to 112 samples on
board (552 with Max)

Real time monitoring of
sample and electrophoresis
timing

Intuitive buffer and reagent
volume monitoring

The intuitive V8 system software provides ease of operation and plenty of user-defined options. Patients results can also be integrated into the QuickScan system for integrated reporting with gel results and tracking of treatment progress with the Myeloma Module.

Brand: Helena Bioscience
Origin: UK
Distributor: BioTech Services

Photos from BioTech Services's post 16/10/2025

New era for ๐—˜๐—ฆ๐—ฅ testing!
Worldโ€™s one & only fully automated ๐—˜๐—ฆ๐—ฅ analyzer that follows all criteria of ๐—ช๐—ฒ๐˜€๐˜๐—ฒ๐—ฟ๐—ด๐—ฟ๐—ฒ๐—ป ๐— ๐—ฒ๐˜๐—ต๐—ผ๐—ฑ!

Westergren is the gold standard method for ESR testing & It's all criteria is given below:
1. Glass pipette with 200mm height
2. Inner diameter of pipette 2.55mm
3. 4:1 dilution with sodium citrate
4. 90ยฐ vertical position
5. Time: 60 minute
6. Temp. should between 18-25ยฐC

Our ๐‘๐‘ ๐Œ๐ž๐œ๐ก๐š๐ญ๐ซ๐จ๐ง๐ข๐œ๐ฌ follows all criteria of westergren method. So, your confidence level will increase a lot when you will start use our ๐‘๐‘ ๐Œ๐ž๐œ๐ก๐š๐ญ๐ซ๐จ๐ง๐ข๐œ๐ฌ instrument ๐Ÿฅฐ

Model: Starrsed-NSTA
Brand: RR Mechatronics
Origin: Netherlands

14/10/2025

Freeliteยฎ assays play a pivotal role in accurate diagnosis, treatment monitoring, and disease management to provide a better patient outcome.

Read these patient cases which reinforce why Freelite assays have been trusted by the medical community worldwide for over 20 years. http://spr.ly/6180xb1Jg

13/10/2025

๐’๐ฒ๐ฌ๐ฆ๐ž๐ฑ ๐’๐ฅ๐ข๐๐ž ๐๐ซ๐ž๐ฉ๐š๐ซ๐š๐ญ๐ข๐จ๐ง ๐”๐ง๐ข๐ญ ๐ฐ๐ข๐ญ๐ก ๐ƒ๐ข๐ ๐ข๐ญ๐š๐ฅ ๐ˆ๐ฆ๐š๐ ๐ข๐ง๐  ๐’๐ฒ๐ฌ๐ญ๐ž๐ฆ!
Itโ€™s an automated system for creating blood smears and performing staining.
It produces consistent, high-quality slides for microscopic analysis.
These units automate the entire process from dispensing blood onto a slide to staining it, ensuring standardized and reproducible results by adjusting parameters like sample volume, speed, and spreader angle based on the blood's hematocrit (HCT) value. This reduces operator variability and improves diagnostic quality.

26/09/2025

Special Protein Test Analyzer

The Optilite assay menu includes tests for Immunoglobulins (IgG, IgA, IgM, IgD, IgE), Free Light Chains (Kappa, Lambda), Subclasses (IgG1, IgG2, IgG3, IgG4, IgA1, IgA2), Complement proteins, Specific proteins (Haptoglobin, Prealbumin, Lipoprotein(a), Rheumatoid Factor), and CNS assays (Low Level Albumin, IgA CSF, IgG CSF).
These assays run on the Optiliteยฎ analyser, a dedicated platform for special protein testing.

All assay panels:
Monoclonal Gammopathies
Immunoglobulins
Ig Subclasses
Complement
Central Nervous System Disorders
Renal Function
Specifc Proteins

26/09/2025

๐™Š๐™ฅ๐™ฉ๐™ž๐™ก๐™ž๐™ฉ๐™š ๐™ž๐™จ ๐™– ๐™›๐™ช๐™ก๐™ก๐™ฎ ๐™–๐™ช๐™ฉ๐™ค๐™ข๐™–๐™ฉ๐™š๐™™ ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ ๐™–๐™ฃ๐™–๐™ก๐™ฎ๐™ฏ๐™š๐™ง ๐™จ๐™ฎ๐™จ๐™ฉ๐™š๐™ข ๐™™๐™š๐™ซ๐™š๐™ก๐™ค๐™ฅ๐™š๐™™ ๐™—๐™ฎ ๐™๐™๐™š ๐˜ฝ๐™ž๐™ฃ๐™™๐™ž๐™ฃ๐™œ ๐™Ž๐™ž๐™ฉ๐™š ๐™‚๐™ง๐™ค๐™ช๐™ฅ, ๐™ž๐™ฃ ๐™ฅ๐™–๐™ง๐™ฉ๐™ฃ๐™š๐™ง๐™จ๐™๐™ž๐™ฅ ๐™ฌ๐™ž๐™ฉ๐™ ๐™๐™๐™š๐™ง๐™ข๐™ค ๐™๐™ž๐™จ๐™๐™š๐™ง ๐™Ž๐™˜๐™ž๐™š๐™ฃ๐™ฉ๐™ž๐™›๐™ž๐™˜, ๐™›๐™ค๐™ง ๐™ช๐™จ๐™š ๐™ž๐™ฃ ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ฉ๐™ž๐™˜ ๐™ก๐™–๐™—๐™ค๐™ง๐™–๐™ฉ๐™ค๐™ง๐™ž๐™š๐™จ.

๐™„๐™ฉ ๐™ช๐™จ๐™š๐™จ ๐™ค๐™ฅ๐™ฉ๐™ž๐™ข๐™ž๐™ฏ๐™š๐™™ ๐˜ฝ๐™ž๐™ฃ๐™™๐™ž๐™ฃ๐™œ ๐™Ž๐™ž๐™ฉ๐™š ๐™–๐™จ๐™จ๐™–๐™ฎ๐™จ ๐™›๐™ค๐™ง ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ๐™จ, ๐™ค๐™›๐™›๐™š๐™ง๐™ž๐™ฃ๐™œ ๐™š๐™›๐™›๐™ž๐™˜๐™ž๐™š๐™ฃ๐™˜๐™ฎ, ๐™–๐™˜๐™˜๐™ช๐™ง๐™–๐™˜๐™ฎ, ๐™–๐™ฃ๐™™ ๐™–๐™ช๐™ฉ๐™ค๐™ข๐™–๐™ฉ๐™ž๐™ค๐™ฃ ๐™ž๐™ฃ ๐™ฅ๐™ง๐™ค๐™˜๐™š๐™จ๐™จ๐™š๐™จ ๐™ก๐™ž๐™ ๐™š ๐™จ๐™–๐™ข๐™ฅ๐™ก๐™š ๐™™๐™ž๐™ก๐™ช๐™ฉ๐™ž๐™ค๐™ฃ, ๐™ง๐™š๐™–๐™œ๐™š๐™ฃ๐™ฉ ๐™ก๐™ค๐™–๐™™๐™ž๐™ฃ๐™œ, ๐™–๐™ฃ๐™™ ๐™–๐™ฃ๐™ฉ๐™ž๐™œ๐™š๐™ฃ ๐™š๐™ญ๐™˜๐™š๐™จ๐™จ ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™˜๐™ฉ๐™ž๐™ค๐™ฃ.

๐™Š๐™ฅ๐™ฉ๐™ž๐™ก๐™ž๐™ฉ๐™š ๐™ž๐™จ ๐™ช๐™จ๐™š๐™™ ๐™ž๐™ฃ ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ฉ๐™ž๐™˜ ๐™ก๐™–๐™—๐™ค๐™ง๐™–๐™ฉ๐™ค๐™ง๐™ž๐™š๐™จ ๐™›๐™ค๐™ง ๐™– ๐™ฌ๐™ž๐™™๐™š ๐™ซ๐™–๐™ง๐™ž๐™š๐™ฉ๐™ฎ ๐™ค๐™› ๐™จ๐™ฅ๐™š๐™˜๐™ž๐™–๐™ก ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ ๐™ฉ๐™š๐™จ๐™ฉ๐™ž๐™ฃ๐™œ, ๐™ž๐™ฃ๐™˜๐™ก๐™ช๐™™๐™ž๐™ฃ๐™œ ๐™ฉ๐™๐™š ๐™™๐™ž๐™–๐™œ๐™ฃ๐™ค๐™จ๐™ž๐™จ ๐™–๐™ฃ๐™™ ๐™ข๐™ค๐™ฃ๐™ž๐™ฉ๐™ค๐™ง๐™ž๐™ฃ๐™œ ๐™ค๐™› ๐™˜๐™ค๐™ฃ๐™™๐™ž๐™ฉ๐™ž๐™ค๐™ฃ๐™จ ๐™ก๐™ž๐™ ๐™š ๐™ข๐™ช๐™ก๐™ฉ๐™ž๐™ฅ๐™ก๐™š ๐™ข๐™ฎ๐™š๐™ก๐™ค๐™ข๐™–.
๐™„๐™ฉ ๐™˜๐™–๐™ฃ ๐™–๐™ก๐™จ๐™ค ๐™—๐™š ๐™ช๐™จ๐™š๐™™ ๐™›๐™ค๐™ง ๐™˜๐™๐™–๐™ง๐™–๐™˜๐™ฉ๐™š๐™ง๐™ž๐™ฏ๐™ž๐™ฃ๐™œ ๐™˜๐™š๐™ฃ๐™ฉ๐™ง๐™–๐™ก ๐™ฃ๐™š๐™ง๐™ซ๐™ค๐™ช๐™จ ๐™จ๐™ฎ๐™จ๐™ฉ๐™š๐™ข ๐™™๐™ž๐™จ๐™ค๐™ง๐™™๐™š๐™ง๐™จ ๐™—๐™ฎ ๐™–๐™ฃ๐™–๐™ก๐™ฎ๐™ฏ๐™ž๐™ฃ๐™œ ๐™˜๐™š๐™ง๐™š๐™—๐™ง๐™ค๐™จ๐™ฅ๐™ž๐™ฃ๐™–๐™ก ๐™›๐™ก๐™ช๐™ž๐™™ (๐˜พ๐™Ž๐™) ๐™ฅ๐™ง๐™ค๐™ฉ๐™š๐™ž๐™ฃ๐™จ

28/08/2025

๐— ๐˜‚๐—น๐˜๐—ถ๐—ฝ๐—น๐—ฒ ๐— ๐˜†๐—ฒ๐—น๐—ผ๐—บ๐—ฎ: Signs & Symptoms

28/08/2025

Watch this short video for an overview of warning signs to diagnostic investigations of ๐— ๐˜‚๐—น๐˜๐—ถ๐—ฝ๐—น๐—ฒ ๐— ๐˜†๐—ฒ๐—น๐—ผ๐—บ๐—ฎ, so you can help improve earlier diagnosis!

07/08/2025

How many parameters you will get in ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ from a Hematology analyzer?
๐—ฆ๐˜†๐˜€๐—บ๐—ฒ๐˜… ๐—ซ๐—ก-๐Ÿฑ๐Ÿฑ๐Ÿฌ gives you ๐Ÿญ๐Ÿฐ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€ from ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ and all parameters have clinical benefits!

The ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ count reflects the erythropoietic activity of bone marrow and is thus useful in both diagnosing anemias and monitoring bone marrow response to therapy.

๐—Ÿ๐—ถ๐˜€๐˜ ๐—ผ๐—ณ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€ ๐—ถ๐—ป ๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ ๐— ๐—ผ๐—ฑ๐—ฒ:
1. RET #
2. RET%
3. IRF
4. LFR
5. MFR
6. HFR
7. RET-HE
8. DELTA-HE
9. HYPO-HE
10. HYPER-HE
11. RBC-HE
12. PLT-O
13. IPF #
14. IPF%

๐—–๐—น๐—ถ๐—ป๐—ถ๐—ฐ๐—ฎ๐—น ๐—ฏ๐—ฒ๐—ป๐—ฒ๐—ณ๐—ถ๐˜๐˜€ ๐—ผ๐—ณ ๐˜๐—ต๐—ผ๐˜€๐—ฒ ๐—ฝ๐—ฎ๐—ฟ๐—ฎ๐—บ๐—ฒ๐˜๐—ฒ๐—ฟ๐˜€:

๐—ฅ๐—ฒ๐˜๐—ถ๐—ฐ๐˜‚๐—น๐—ผ๐—ฐ๐˜†๐˜๐—ฒ # & %: A reticulocyte count checks to see if your bone marrow is making the right amount of red blood cells when old ones die off. If you have too few, your tissues may not get enough oxygen. If you have too many, you could be at risk for blood clots or other health concerns. Reticulocyte counts also help differentiate between different types of anemia, specifically identifying whether the anemia is due to decreased red blood cell production (hypoproliferative) or increased red blood cell destruction or loss (hyperproliferative).

๐ˆ๐ฆ๐ฆ๐š๐ญ๐ฎ๐ซ๐ž ๐‘๐ž๐ญ๐ข๐œ๐ฎ๐ฅ๐จ๐œ๐ฒ๐ญ๐ž ๐…๐ซ๐š๐œ๐ญ๐ข๐จ๐ง: It can distinguish between hypo-proliferative (e.g., anemia of chronic disease), ineffective (e.g., some megaloblastic anemias), and hemolytic anemias (e.g., sickle cell anemia). For example, in hemolytic anemias, where red blood cell destruction is increased, the IRF will be high, indicating the bone marrow is working to compensate.
In contrast, in anemia of chronic disease, the IRF may be low, reflecting a suppressed bone marrow response.
It can help assess the effectiveness of bone marrow recovery in patients with aplastic anemia. For example, in patients with acute leukemia, a rising IRF after chemotherapy can indicate that the bone marrow is starting to produce new red blood cells.

๐‡๐…๐‘, ๐Œ๐…๐‘ & ๐‹๐…๐‘: High-fluorescence reticulocytes (HFR), middle-fluorescence reticulocytes (MFR), and low-fluorescence reticulocytes (LFR) are subpopulations of reticulocytes, which are immature red blood cells, identified by flow cytometry based on their RNA content and fluorescence intensity. The increase in HFR and MFR can be an early indicator of iron deficiency, even before a significant drop in hemoglobin levels.
HFR: Represents the most immature reticulocytes, with the highest RNA content, and its increase indicates a heightened bone marrow response to anemia.
MFR: Represents immature reticulocytes, with moderate RNA content, and its increase also indicates increased erythropoiesis.
LFR: Represents more mature reticulocytes, with lower RNA content.

๐‘๐„๐“-๐‡๐ž: (Reticulocyte Hemoglobin Equivalent) is a valuable tool in assessing iron status and erythropoiesis. It offers several clinical benefits, including early detection of iron deficiency, monitoring response to iron therapy, and potentially guiding treatment decisions in various conditions like anemia of chronic disease and nephrological disorders.
RET-He is particularly useful in populations like pregnant women, patients with kidney disease, and those with anemia of chronic disease, where iron deficiency can be a significant concern.
Unlike serum ferritin, RET-He is not affected by inflammation or infection, making it a more reliable indicator of iron status in these situations.

๐‘๐๐‚-๐‡๐ž: If increase RBC-He than it causes for Polycythemia, higher risk of blood clots & if RBC-He decreases than it causes for Fatigue, Shortness of breath and thalassemia.

๐‡๐˜๐๐Ž-๐‡๐ž & ๐‡๐˜๐๐„๐‘-๐‡๐ž: HYPO-He and HYPER-He are hematological parameters that can be used to diagnose and monitor iron deficiency and other erythropoietic disorders. HYPO-He, the percentage of red blood cells with low hemoglobin content, is particularly useful in identifying iron deficiency, even in its subclinical stages. HYPER-He, the percentage of red blood cells with high hemoglobin content, can be indicative of other conditions like spherocytosis or liver disease.

๐ƒ๐„๐‹๐“๐€-๐‡๐ž: Delta-He, calculated as the difference between Ret-He and RBC-He.
Delta-He a novel marker of inflammation predicting mortality and ESA(Erythropoiesis Stimulating Agent) response in peritoneal dialysis patients. It also serves as a sensitive indicator of iron availability for red blood cell production.

๐—ฃ๐—Ÿ๐—ง-๐—ข: PLT-Optical methods can minimize interference from small RBCs, RBC fragments, and other particles that can falsely elevate platelet counts in traditional impedance method. PLT-O, often utilizing fluorescent staining and the reticulocyte (RET) channel, excels in differentiating platelets from interfering particles like small red blood cells (RBCs) and cell debris. This leads to more accurate platelet counts, especially in cases of low platelet counts or suspected interference.

๐—œ๐—ฃ๐—™ # & ๐—œ๐—ฃ๐—™ %: The immature platelet fraction (IPF) is a valuable biomarker in hematology, offering clinical benefits in diagnosing and managing thrombocytopenia, monitoring thrombopoietic recovery, and assessing cardiovascular risk. It helps differentiate between various causes of low platelet counts and can guide treatment decisions related to platelet transfusions and antiplatelet therapies.

Want your business to be the top-listed Government Service in Kalabaga?

Click here to claim your Sponsored Listing.

Location

Telephone

Address


57/3 & 57/4, 9th Floor, ENA Tower, , Bir Uttam Kazi Nurruzzaman Road, , Panthapath, Kalabagan
Kalabaga

Opening Hours

Monday 09:30 - 18:00
Tuesday 09:30 - 18:00
Wednesday 09:30 - 18:00
Thursday 09:30 - 18:00
Saturday 09:30 - 18:00
Sunday 09:30 - 18:00